Transformers for use in medical applications

Transformers that satisfy special demands

Special demands are placed on transformers for the supply of rooms used for medical purposes in hospitals, physicians’ practices and nursing homes. They are regulated by DIN VDE 0100-710: 2012-10, among other standards. This is necessary on the one hand because it involves the immediate safety patients and, on the other hand, the safety and reliability of the current supply, e.g. in operating rooms or the supply of intensive care patients. Fluctuations and failures of the voltage supply can have deadly consequences in such applications. ISMET transformers for the supply of rooms used for medical applications are designed in accordance with these regulations and satisfy all requirements down to the last detail.

View all products

Single-phase transformers for the supply of medical roomsThree-phase transformers for the supply of medical roomsSingle-phase isolating transformers

KOP

Single-phase transformers for the supply of medical rooms

Single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-15 as well as DIN VDE 0107/10.94. Shielding winding between primary and secondary winding. In every branch one PTC-resistor wrapped. Connections: Terminals with screwed connection, prepared for safety class II, 50/60 Hz, ta 40°C, dip impregnation.

P: 3,15 - 8,00 kVAUPRI: 230 VUSEC: 115 V

View product

TG-MED-1

Single-phase transformers for the supply of medical rooms

Single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 and.EN 60601-1, DIN VDE 0107/10.94. Primary mains cable, secondary two parallel grounding outlets. Primary fuse. Transformer in sheet steel casing, color RAL 7035, type of enclosure IP 43, safety class I, 50/60 Hz, ta 40°C.

P: 250 - 500 VAUPRI: 230 VUSEC: 230 V

View product

TG-MED-2

Single-phase transformers for the supply of medical rooms

Single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-4 and.EN 60601-1, DIN VDE 0107/10.94. Primary mains cable, secondary two parallel grounding outlets. Primary fuse. Transformer in sheet steel casing, color RAL 7035, type of enclosure IP 43, safety class I, 50/60 Hz, ta 40°C.

P: 1000 VAUPRI: 230 VUSEC: 230 V

View product

KOP-L

Single-phase transformers for the supply of medical rooms

Single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-15 as well as DIN VDE 0107/10.94. Shielding winding between primary and secondary winding. In every branch one PTC-resistor wrapped. Connections: Terminals with screwed connection, prepared for safety class II, 50/60 Hz, ta 40°C, dip impregnation.

P: 3,15 - 8,00 kVAUPRI: 230 VUSEC: 115 V

View product

KOP-VG

Single-phase transformers for the supply of medical rooms

Single-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-15 as well as DIN VDE 0107/10.94. Shielding winding between primary and secondary winding. In every branch one PTC-resistor wrapped. Connections: Terminals with screwed connection, safety class II, 50/60 Hz, ta 40°C, Transformer in blocktype encapsulated, protection system IP 65. Connection to terminals in a connector box.

P: 3,15 - 8,00 kVAUPRI: 230 VUSEC: 115 V

View product

DOP

Three-phase transformers for the supply of medical rooms

Three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-15 as well as DIN VDE 0107/10.94. Shielding winding between primary and secondary winding. In every branch one PTC-resistor wrapped. Connections: Terminals with screwed connection, prepared for safety class II, 50/60 Hz, ta 40°C, dip impregnation.

P: 3,15 - 10,00 kVAUPRI: 400 VUSEC: 230 V

View product

DOP-L

Three-phase transformers for the supply of medical rooms

Three-phase isolating transformer according to DIN EN 61558, VDE 0570, part 2-15 as well as DIN VDE 0107/10.94. Shielding winding between primary and secondary winding. In every branch one PTC-resistor wrapped. Connections: Terminals with screwed connection, prepared for safety class II, 50/60 Hz, ta 40°C, dip impregnation.

P: 3,15 - 10,00 kVAUPRI: 400 VUSEC: 230 V

View product

MTDN-M

Single-phase isolating transformers

Single-phase safety - transformer according to DIN EN 61558, VDE 0570, part 2-6 Terminals with screwed connections (6,3 x 0,8 mm), prepared for safety class II, ta 40°C, 50/60 Hz, dip impregnation. Shielding winding at terminal, insulated foot angles, temperature switch connected with terminals Acc. UL 2601, EN 60601-1, VDE 0570, VDE 0100-710

P: 140 - 980 VAUPRI: 230 VUSEC: 0 - 28 V

View product

One-phase transformers for the supply of rooms used for medical applications

Our one-phase transformers for the supply of rooms used for medical applications fulfil all current standards and regulations. One-phase transformers from ISMET ensure a reliable, uninterruptible voltage supply in operating rooms, to medical devices, automated analysis instruments and dosage administering devices. ISMET offers all necessary categories, designs and sizes of one-phase transformers from stock or with short delivery times. ISMET provides one-phase transformers for the supply of rooms used for medical applications without a housing or in hygienic, easy-to-clean housings with smooth surfaces.

Three-phase transformers for the supply of rooms used for medical applications

Our three-phase transformers for the supply of rooms used for medical applications fulfil all current standards and regulations. Three-phase transformers from ISMET ensure a reliable, uninterruptible voltage supply in operating rooms, to medical devices, automated analysis instruments and dosage administering devices. ISMET offers all necessary categories, designs and sizes of three-phase transformers from stock or with short delivery times. ISMET provides three-phase transformers for the supply of rooms used for medical applications without a housing or in hygienic, easy-to-clean housings with smooth surfaces.

One-phase isolating transformers

One-phase transformers are designed for electrical isolation of current circuits and are thus provided with protective isolation between the input and output winding. Isolating transformers prevent hazards due to accidental simultaneous contact of the earth and live parts. Due to isolation faults in unfavourable situations, parts which are not intended to be live may become live. One-phase isolating transformers in accordance with DIN EN 61558, VDE 0570, part 2-6 from ISMET are delivered with terminals with screw connection, are dip impregnated and prepared for protection class II.

Your contact enquiry for a transformer for use in medical applications